Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
J Pharm Sci ; 113(3): 604-615, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-37758160

RESUMO

The emergence of highly potent therapeutics with low expected clinical doses creates a challenge for analytical characterization of simulated drug product in-use samples. The low expected protein concentration (often µg/mL) and highly charged and sub-optimal sample matrices like 0.9% saline or 5% dextrose make ensuring dose solution stability and characterizing product quality changes difficult. Health authority expectations require analysis of low concentration in-use samples to be completed with suitable assays to ensure little to no changes are occurring during drug product dose preparation and administration, thus ensuring patient safety. However, characterization of these samples for protein concentration, size variants, charge variants and potency often necessitates additional analytical method development to improve sensitivity and compatibility with in-use samples. Here we report the development and qualification of reliable in-use methods to characterize simulated in-use samples to assist during drug product development.


Assuntos
Preparações Farmacêuticas , Humanos , Composição de Medicamentos
2.
Int J Mol Sci ; 24(16)2023 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-37629070

RESUMO

Phagocytosis is one of the key functions of retinal pigment epithelium (RPE) cells, which maintain photoreceptor health by removing photoreceptor outer segments (POSs) that are regularly shed. A deficiency in RPE function to phagocytose POSs may lead to vision loss in inherited retinal diseases and eventually to age-related macular degeneration (AMD) with geographic atrophy. Significant progress has been made in the field of cell replacement therapy for AMD using stem-cell-derived RPE. To test their function, RPE cells are incubated with purified bovine POSs for the demonstration of efficient binding, internalization, and digestion of POSs. Here, we present an image-based method to measure phagocytosis activity by using POSs labeled with a pH-sensitive fluorescent dye, which has low fluorescence at neutral pH outside of the cell and high fluorescence at low pH inside the phagosome. Further, we introduce a unique flow-cytometry-based method for the characterization of POSs by measuring specific markers for POSs such as rhodopsin and opsin. Using this method, we demonstrated a comparable quality of several bovine POS isolation batches and a reliable assessment of POS quality on RPE phagocytosis assay performance when subjected to different stress conditions. This work provides new tools to characterize POSs and insight into RPE phagocytosis assay development for the functional evaluation of RPE cells in the field of cell replacement therapy.


Assuntos
Degeneração Macular , Epitélio Pigmentado da Retina , Animais , Bovinos , Citometria de Fluxo , Neuritos , Neurônios , Fagocitose
3.
Talanta ; 252: 123780, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-35988299

RESUMO

CRISPR (clustered regularly interspaced short palindromic repeats)-associated proteins (Cas) are powerful gene-editing tools used in therapeutic applications. Efforts to minimize off-target cleavage by CRISPR-Cas9 have motivated the development of engineered Cas9 variants. The wild-type (WT) Streptococcus pyogenes (SpCas9) has been engineered into a high-fidelity Cas9 (SpyFi Cas9) that shows promising results in providing high on-target activity (targeting efficiency) while reducing off-target editing (unwanted mutations). This work describes for the first time the development of ultra-high-performance liquid chromatography (UHPLC) and capillary electrophoresis (CE)-based methods for a full characterization of different engineered Cas9 variants, including determination of purity, size variants, isoelectric points (pI), post-translational modifications (PTMs), and functional activities. The purity and size variant characterization were first determined by CE-sodium dodecyl sulfate (SDS). An in vitro DNA cleavage assay using an automated electrophoresis tool was employed to investigate the functional activity of ribonucleoprotein (RNP) complexes derived from Cas9 variants. The pIs of the engineered Cas9 proteins were determined by imaged capillary isoelectric focusing (icIEF), while intact mass measurements were performed by reversed-phase (RP)-UHPLC coupled with high-resolution mass spectrometry (HRMS). A peptide mapping assay based on LC-UV-MS/MS using endoproteinase Lys-C under non-reducing conditions was developed to confirm amino acid sequences, allowing differentiation of SpyFi Cas9 from WT SpCas9. The potential of using a low-resolution MS detector, especially for a GMP environment, as a low-cost and simple method to identify SpyFi Cas9 is discussed.


Assuntos
Sistemas CRISPR-Cas , Espectrometria de Massas em Tandem , Cromatografia Líquida de Alta Pressão , Proteína 9 Associada à CRISPR/genética , Proteína 9 Associada à CRISPR/química , Proteína 9 Associada à CRISPR/metabolismo , Eletroforese Capilar
4.
J Chromatogr A ; 1682: 463518, 2022 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-36155073

RESUMO

Affinity liquid chromatography using FcRn and FcγRIIIa columns can provide important information on the drug effector functions and the unique PK/PD properties of therapeutic mAbs. In this study, we propose a unique strategy to improve the performance of affinity chromatography by applying pH-gradient programs that incorporate multi-isocratic and negative gradient segments. These alternative gradient programs are known to greatly improve the separation of large solutes that follow a "bind-and-elute" type retention behavior. First, judicious optimization of the mobile phase compositions was performed to obtain a linear pH response. Then, with the developed strategy using multi-isocratic analysis conditions, the FcRn affinity separation selectivity for the analysis of oxidized mAb species was greatly improved. Furthermore, the introduction of negative gradient segments after each eluted peak improved the resolution between multiple glycosylated mAb species on the FcγRIIIa column. Therefore, this work provides a new strategy to improve the performance of affinity chromatography with mAb species, and could assist in the development of more accurate binding assays for important critical quality attributes related to FcRn and FcγRIIIa binding.


Assuntos
Produtos Biológicos , Anticorpos Monoclonais/metabolismo , Cromatografia de Afinidade , Cromatografia Líquida , Glicosilação
5.
Talanta ; 246: 123519, 2022 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-35525056

RESUMO

Fc-fusion proteins represent a successful class of biopharmaceutical products. They are considered highly heterogeneous products due to the common degradation of amino acids that occurs during their production in upstream and downstream processes (e.g., oxidation and deamidation) and, above all, their complex glycosylation profile. Multi-dimensional liquid chromatography-mass spectrometry (mD-LC-MS) has recently gained much interest for process analytical technology, enabling the integration of this analytical technology in production and purification environments. In this study, an online mD-LC-MS/MS peptide mapping method was developed for monitoring multiple quality attributes, including the N-glycosylation state of a complex Fc-fusion protein, which is made by combining two heavily glycosylated cytokines with an Fc domain. This fully automated workflow includes sample purification, reduction, digestion, peptide mapping, and subsequent mass spectrometric analysis. Two immobilized enzyme cartridges based on trypsin and Lys-C protease were employed to generate a detailed glycosylation mapping, as trypsin allowed the identification of only one of four glycosylation sites, while Lys-C was more informative for two other sites. Site-specific glycosylation information such as antennarity, sialyation, and core fucosylation state was also determined. In addition to glycans, other post-translational modifications could be monitored simultaneously during the cell culture production processes by the mD-LC-MS/MS approach. In summary, the generated data demonstrate the applicability of mD-LC-MS for the monitoring and trending of multiple attributes for complex antibody formats over production processes in an automated and fast manner, compared to the complex and time-consuming traditional offline assays.


Assuntos
Anticorpos Monoclonais , Espectrometria de Massas em Tandem , Anticorpos Monoclonais/química , Técnicas de Cultura de Células , Cromatografia Líquida/métodos , Mapeamento de Peptídeos/métodos , Tripsina
6.
J Chromatogr A ; 1672: 463067, 2022 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-35462311

RESUMO

Online monitoring of quality attributes (QAs) directly within the bioreactor can provide the basis for advanced modes of protein production including process intensification, smart manufacturing, and real-time release testing. The development of technologies to enable monitoring of QAs has been highly challenging due to the relative immaturity of commercial technologies for online analysis, generally low abundance of the attributes requiring highly specialized analytics not always amenable to automation, and the significant burden on development organizations to demonstrate the comparability and suitability of the online technologies resulting in low investment interest. In this study, we present for the first time a fully automated and highly flexible method for direct monitoring of QAs from the bioreactor. The method combines an automated sampling system and multi-dimensional (mD) LC-MS/MS technology to provide a means of quantifying post-translational modifications (PTMs) during the cell culture process and making real-time process decisions based on the resulting peptide mapping data. In doing so, a wide variety of PTMs can be identified and quantified including, but not limited to, oxidation, succinimidation, deamidation, isomerization, and glycosylation. The potential of this analytical workflow for the monitoring and trending of multiple attributes during cell culture production processes was first demonstrated with a standard IgG1 antibody over the production process. Then, the online workflow was applied to a complex format Fc-fusion protein to monitor sialylation. The ability to monitor sialylation offers a unique opportunity to develop process control schemes to ensure the final product meets quality specifications, showing the potential of this workflow in the context of online process analytical technology (PAT).


Assuntos
Anticorpos Monoclonais , Espectrometria de Massas em Tandem , Anticorpos Monoclonais/química , Automação , Reatores Biológicos , Técnicas de Cultura de Células , Cromatografia Líquida/métodos
7.
Electrophoresis ; 43(9-10): 1050-1058, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35245390

RESUMO

An international team spanning 19 sites across 18 biopharmaceutical and in vitro diagnostics companies in the United States, Europe, and China, along with one regulatory agency, was formed to compare the precision and robustness of imaged CIEF (ICIEF) for the charge heterogeneity analysis of the National Institute of Standards and Technology (NIST) mAb and a rhPD-L1-Fc fusion protein on the iCE3 and the Maurice instruments. This information has been requested to help companies better understand how these instruments compare and how to transition ICIEF methods from iCE3 to the Maurice instrument. The different laboratories performed ICIEF on the NIST mAb and rhPD-L1-Fc with both the iCE3 and Maurice using analytical methods specifically developed for each of the molecules. After processing the electropherograms, statistical evaluation of the data was performed to determine consistencies within and between laboratory and outlying information. The apparent isoelectric point (pI) data generated, based on two-point calibration, for the main isoform of the NIST mAb showed high precision between laboratories, with RSD values of less than 0.3% on both instruments. The SDs for the NIST mAb and the rhPD-L1-Fc charged variants percent peak area values for both instruments are less than 1.02% across different laboratories. These results validate the appropriate use of both the iCE3 and Maurice for ICIEF in the biopharmaceutical industry in support of process development and regulatory submissions of biotherapeutic molecules. Further, the data comparability between the iCE3 and Maurice illustrates that the Maurice platform is a next-generation replacement for the iCE3 that provides comparable data.


Assuntos
Produtos Biológicos , Eletroforese Capilar , Eletroforese Capilar/métodos , Focalização Isoelétrica/métodos , Laboratórios , Isoformas de Proteínas
8.
Talanta ; 234: 122628, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34364437

RESUMO

An international study was conducted to evaluate the performance and reliability of an online multi-dimensional (mD)-LC-MS/MS approach for the characterization of antibody charge variants. The characterization of antibody charge variants is traditionally performed by time-consuming, offline isolation of charge variant fractions by ion exchange chromatography (IEC) that are subsequently subjected individually to LC-MS/MS peptide mapping. This newly developed mD-LC-MS/MS approach enables automated and rapid characterization of charge variants using much lower sample requirements. This online workflow includes sample reduction, digestion, peptide mapping, and subsequent mass spectrometric analysis within a single, fully-automated procedure. The benefits of using online mD-LC-MS/MS for variant characterization include fewer handling steps, a more than 10-fold reduction in required sample amount, reduced sample hold time as well as a shortening of the overall turnaround time from weeks to few days compared to standard offline procedures. In this site-to-site comparison study, we evaluated the online peptide mapping data collected from charge variants of trastuzumab (Herceptin®) across three international laboratories. The purpose of this study was to compare the overall performance of the online mD-LC-MS/MS approach for antibody charge variant characterization, with all participating sites employing different mD-LC-MS/MS setups (e.g., instrument vendors, modules, columns, CDS software). The high sequence coverage (95%-97%) obtained in each laboratory, enabled a reproducible generation of tryptic peptides and the comparison of values of the charge variants. Results obtained at all three participating sites were in good agreement, highlighting the reliability and performance of this approach, and correspond with data gained by the standard offline procedure. Overall, our results underscore of the benefit mD-LC-MS/MS technology for therapeutic antibody characterization, confirming its potential to become an important tool in the toolbox of protein characterization scientists.


Assuntos
Laboratórios , Espectrometria de Massas em Tandem , Anticorpos Monoclonais , Cromatografia Líquida , Humanos , Reprodutibilidade dos Testes
9.
J Pharm Sci ; 110(6): 2362-2371, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33652014

RESUMO

Constrained peptides (CPs) have emerged as attractive candidates for drug discovery and development. To fully unlock the therapeutic potential of CPs, it is crucial to understand their physical stability and minimize the formation of aggregates that could induce immune responses. Although amyloid like aggregates have been researched extensively, few studies have focused on aggregates from other peptide scaffolds (e.g., CPs). In this work, a streamlined approach to effectively profile the nature and formation pathway of CP aggregates was demonstrated. Aggregates of various sizes were detected and shown to be amorphous. Though no major changes were found in peptide structure upon aggregation, these aggregates appeared to have mixed natures, consisting of primarily non-covalent aggregates with a low level of covalent species. This co-existence phenomenon was also supported by two kinetic pathways observed in time- and temperature-dependent aggregation studies. Furthermore, a stability study with 8 additional peptide variants exhibited good correlation between aggregation propensity and peptide hydrophobicity. Therefore, a dual aggregation pathway was proposed, with the non-covalent aggregates driven by hydrophobic interactions, whereas the covalent ones formed through disulfide scrambling. Overall, the workflow presented here provides a powerful strategy for comprehensive characterization of peptide aggregates and understanding their mechanisms of formation.


Assuntos
Amiloide , Peptídeos , Dissulfetos , Interações Hidrofóbicas e Hidrofílicas , Fragmentos de Peptídeos
10.
Analyst ; 146(3): 747-769, 2021 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-33410843

RESUMO

Accelerated development of new therapeutics in an increasingly competitive landscape requires the use of high throughput analytical platforms. In addition, the complexity of novel biotherapeutic formats (e.g. fusion proteins, protein-polymer conjugates, co-formulations, etc.) reinforces the need to improve the selectivity and resolution of conventional one-dimensional (1D) liquid chromatography (LC). Liquid chromatography-mass spectrometry (LC-MS)-based technologies such as native LC-MS for intact mass analysis or peptide mapping (also called bottom-up approach)-based multi-attribute methods (MAM) have already demonstrated their potential to complement the conventional analytical toolbox for monoclonal antibody (mAb) characterization. Two-dimensional liquid-chromatography (2D-LC-MS) methods have emerged in the last ten years as promising approaches to address the increasing analytical challenges faced with novel antibody formats. However, off-line sample preparation procedures are still required for conventional 1D and 2D-LC-MS methods for the in-depth variant characterization at the peptide level. Multi-dimensional LC-MS (mD-LC-MS) combine sample preparation and multi-level (i.e. intact, reduced, middle-up and peptide) analysis within the same chromatographic set-up. This review presents an overview of the benefits and limitations of mD-LC-MS approaches in comparison to conventional chromatographic methods (i.e. 1D-LC-UV methods at intact protein level and 1D-LC-MS methods at peptide level). The current analytical trends in antibody characterization by mD-LC-MS approaches, beyond the 2D-LC-MS workhorse, are also reviewed, and our vision on a more integrated multi-level mD-LC-MS characterization platform is shared.


Assuntos
Imunoconjugados , Espectrometria de Massas em Tandem , Anticorpos Monoclonais , Cromatografia Líquida , Imunoconjugados/análise , Peptídeos
11.
Artigo em Inglês | MEDLINE | ID: mdl-32971367

RESUMO

The successful application of monoclonal antibodies (mAb) in oncology and autoimmune diseases paved the way for the development of therapeutic antibodies with a wider range of structural and physico-chemical properties. A pH-gradient combining 2-(N-morpholino)ethanesulfonic (MES) and 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid (HEPES) buffers and mediated with potassium chloride was developed to sufficiently retain acidic mAbs (pI < 7) in cation exchange chromatography (CEX), while keeping suitable separation performance for basic mAbs (pI > 7). Firstly, the MES and HEPES buffers were individually evaluated in their useful pH range by applying a salt gradient. The performance of a salt-mediated pH gradient combining the MES and HEPES buffers was then compared to a commercial pH gradient kit. The developed conditions were found superior to the salt-gradient approaches and provided a useful alternative to commercial pH gradient kits. In this study, the developed conditions were applied to separate a bispecific antibody (BsAb) from its two parental mAbs.


Assuntos
Anticorpos Monoclonais , Cromatografia por Troca Iônica/métodos , Cloreto de Sódio/química , Ácidos Alcanossulfônicos/química , Anticorpos Monoclonais/análise , Anticorpos Monoclonais/química , Anticorpos Monoclonais/isolamento & purificação , HEPES/química , Concentração de Íons de Hidrogênio , Morfolinas/química
12.
Anal Chem ; 92(19): 13420-13426, 2020 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-32901474

RESUMO

On-line bottom-up approaches have recently emerged as promising alternatives to standard off-line processes for characterizing post-translational modifications (PTMs) of therapeutic monoclonal antibodies (mAbs). The benefits of on-line processing include reductions in required sample amount and sample handling, as well as reducing the overall turnaround time. However, shortening digestion time for the on-line approach of an intact mAb can cause incomplete peptide cleavages, leading to low sequence coverage and poor repeatability of analyses. For the first time, we describe a novel, automated targeted bottom-up strategy consisting of reducing the complexity of intact mAb by digesting the product into small ∼25 kDa fragments, followed by an on-line peptide mapping analysis of each fragment. For this purpose, a four-dimensional-liquid chromatography/mass spectrometry (4D-LC/MS) method was developed using an immobilized IdeS-high-performance liquid chromatography (HPLC) column as a first dimension (1D) for on-line digestion, followed by a (2D) on-column reversed-phase liquid chromatography (RPLC) for reduction and fragments separation. Then, only one fragment was selected for digestion using a (3D) immobilized trypsin cartridge and, finally, the obtained peptides were analyzed by (4D) RPLC-MS. This strategy considerably improved the on-line digestion efficiency with higher sequence coverages (LC and HC >97%), thus allowing various PTMs including oxidation, deamidation, and isomerization located in the complementarity-determining regions (CDRs), as well as N-glycans present on the Fc/2 fragment, to be monitored with similar sensitivity to those obtained with standard off-line approaches. Additional investigations at a middle-up level were also performed via a three-dimensional-LC/MS (3D-LC/MS) approach within the same system, demonstrating the feasibility to achieve a multilevel comprehensive characterization of mAbs.


Assuntos
Anticorpos Monoclonais/análise , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas , Proteínas Recombinantes/análise
13.
Bioanalysis ; 12(15): 1061-1069, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32735119

RESUMO

Background: Polyethylene glycolylation (PEGylation) technology is a long-acting delivery platform used to increase the half-life of protein therapeutics. Quantitation of PEGylated anti-Factor D Fab (PEG-aFD) poses bioanalytical challenges. Results: An ELISA was developed to determine total Fab concentration in cynomolgus monkey serum following intravitreal administration of PEG-aFD. However, assay characterization showed a low recovery of about 25% for free unconjugated Fab whereas recovery for PEG-conjugated Fab was within 80-120%. To overcome this challenge, an immunoaffinity liquid chromatography tandem mass spectrometry (IA LC-MS/MS) assay was developed, achieving recovery within 80-120% for both free and conjugated Fab. Conclusion: Immunoaffinity LC-MS/MS is more suitable than ELISA to accurately quantify the total protein concentration of PEG-aFD in cynomolgus monkey serum.


Assuntos
Cromatografia Líquida/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Espectrometria de Massas em Tandem/métodos , Animais , Haplorrinos , Humanos
14.
Anal Chem ; 92(12): 8506-8513, 2020 06 16.
Artigo em Inglês | MEDLINE | ID: mdl-32441930

RESUMO

Monitoring of post-translational modifications (PTMs) in therapeutic monoclonal antibodies (mAbs) is essential during their production in both upstream and downstream processes. However, characterization of PTMs using a conventional peptide mapping procedure requires time-consuming and labor-intensive offline sample preparation steps. This work describes for the first time, the implementation of a Protein-A affinity chromatography column as the first dimension (1D) in a multidimensional LC (3D and 4D) setup for the automated characterization of mAb variants from harvest cell culture fluid (HCCF) materials at different purification/production steps. A 4D-LC/MS method (Protein-A-Reduction-RPLC-Digestion-RPLC/MS) was developed to determine PTM levels including oxidation, deamidation, and succinimide formation by online peptide mapping analysis. To obtain an accurate and comprehensive profiling of mAb glycosylation patterns at the reduced level, a 3D-LC/MS method (Protein-A-Reduction-RPLC-HILIC/MS) was also developed on the same chromatographic system. Overall, the full workflow (data acquisition and analysis) for both 3D and 4D-LC/MS setups can be completed within less than 1-2 days, compared to weeks with the conventional manual approach. This proof of concept study demonstrates that mD-LC/MS has the potential to be used as a powerful tool to perform a fast and reliable monitoring of PTMs during the manufacturing process for both bioreactor control or as a monitoring assay.


Assuntos
Anticorpos Monoclonais/análise , Automação , Proteína Estafilocócica A/química , Animais , Anticorpos Monoclonais/metabolismo , Células Cultivadas , Cromatografia Líquida , Humanos , Espectrometria de Massas , Proteína Estafilocócica A/metabolismo
15.
J Pharm Biomed Anal ; 182: 113130, 2020 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-32004773

RESUMO

The development of biotherapeutic proteins requires the use of efficient analytical methods to support their manufacturing process and quality control (QC). Analytical approaches at intact and middle-up levels emerged as promising alternatives to bottom-up strategies for protein characterization as they require less sample amount and simplified sample handling, thus reducing the overall turn-around time. This study describes, for the first time, the development of an automated liquid chromatography-mass spectrometry (LC-MS) workflow comprised of an immobilized IdeS-HPLC column for on-line sample digestion, followed by a reversed-phase liquid chromatography (RPLC) for protein subunit separation, and a high-resolution MS for molecular weight analysis. A proof of concept study was described here for the characterization of a therapeutic mAb and a bsAb. For the mAb, this automated workflow enabled rapid characterization of post-translational modifications (PTMs) such as N-glycosylation, glycation and N-terminal lysine. For the bsAb, the same workflow was successfully employed to identify product impurities due to chain pairing. The sample analysis using this workflow can be accomplished within less than one day. This workflow demonstrated its potential as a multi-attribute method for characterization of therapeutic proteins.


Assuntos
Anticorpos Biespecíficos/química , Anticorpos Monoclonais/química , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia de Fase Reversa/métodos , Anticorpos Biespecíficos/análise , Anticorpos Monoclonais/análise , Automação , Espectrometria de Massas/métodos , Peso Molecular
16.
Anal Chem ; 92(6): 4357-4363, 2020 03 17.
Artigo em Inglês | MEDLINE | ID: mdl-32079391

RESUMO

Glycosylation is a common post-translational modification of therapeutic monoclonal antibodies produced in mammalian cells and is considered an important critical quality attribute (CQA), as it is known to impact efficacy, stability, half-life, and immunogenicity. For these reasons, glycosylation requires characterization and close monitoring during the manufacturing process. Due to the complexity of the glycosylation patterns, sophisticated analytical tools with high resolving power are required for the characterization of the glycoforms. This study describes, for the first time, the development and use of an online three-dimensional high-performance liquid chromatography/mass spectrometry (3D-HPLC/MS) approach for the monitoring of glycosylation patterns at the middle-up level. An immobilized IdeS-enzyme column was used in the first dimension for the digestion of mAbs in 10 min. Then, following an online reversed phase liquid chromatography (RPLC) column reduction, the ≈25 kDa proteolytic fragments were analyzed using hydrophilic interaction chromatography (HILIC) coupled to MS. This novel analytical workflow demonstrated the ability to accurately profile glycosylated variants within a total run time of 95 min. To compare the performance of this analytical strategy with a conventional offline procedure (IdeS digestion x reduction-HILIC/MS), a proof of concept study using two mAbs is described here.


Assuntos
Anticorpos Monoclonais/análise , Automação , Anticorpos Monoclonais/metabolismo , Cromatografia Líquida de Alta Pressão , Glicosilação , Espectrometria de Massas
17.
J Chromatogr A ; 1615: 460740, 2020 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-31796250

RESUMO

The identification and quantification of post-translational modifications (PTMs) is a crucial step required during the development of therapeutic proteins. In particular, the characterization of charge variants separated by cation exchange chromatography (CEX) is a tedious process commonly performed with an off-line manual fraction collection followed by peptide mapping. To improve the efficiency of this time-consuming approach, a generic on-line multi-dimensional LC/MS approach was developed for the characterization of various monoclonal antibody (mAb) isotypes and a bi-specific antibody (BsAb). Fractions collected from 1D CEX analysis were consecutively reduced on a 2D reversed phase liquid chromatography (RPLC) column (polyphenyl), digested within 1-2 min using a 3D immobilized trypsin cartridge, and finally the obtained peptides were separated on another 4D RPLC column (C18), and simultaneously identified with a Q Exactive™ mass spectrometer. 2D RPLC columns and 3D trypsin cartridges from different suppliers were compared, as well as the effects of reducing agents. The effect of 2D and 4D RPLC column temperature, and 2D RPLC column mass load were also systematically studied. Under optimal conditions, the multi-dimensional LC/MS system described in this paper is a robust tool for the on-line digestion of proteins and shows high repeatability. Similar levels of oxidation and deamidation were measured using the off-line and on-line approaches for the same stressed samples. The lower amounts of deamidation and isomerization measured at some asparagine and aspartic acid residues by the on-line approach compared to the manual off-line procedure suggest reduced artifacts using the on-line methodology. The multi-dimensional LC/MS described here enables fast, on-line, automated characterization of therapeutic antibodies without the need for off-line fraction collection and sample pre-treatment (manual approach). The entire workflow can be completed within less than one day, compared to weeks with the manual off-line procedure.


Assuntos
Anticorpos Monoclonais/química , Técnicas de Química Analítica/métodos , Cromatografia Líquida , Espectrometria de Massas , Asparagina/química , Mapeamento de Peptídeos , Peptídeos/química , Tripsina , Fluxo de Trabalho
18.
Bioanalysis ; 11(23): 2161-2173, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31701759

RESUMO

Aim: To develop a sensitive hybrid immunoaffinity LC-MS/MS monkey serum assay to quantify multiple components of anti-Factor D; a complex PEGylated Fab biotherapeutic explored as a therapy for age-related macular degeneration. Materials & methods: Immunoaffinity enrichment of PEGylated anti-Factor D Fab, including fully conjugated, partially conjugated and unconjugated (i.e., free) Fab species, using a capture reagent coupled to magnetic beads was performed. The surrogate peptides derived from the therapeutic Fab via trypsin digestion were measured to obtain the total Fab concentrations. Results & conclusion: The method demonstrated the ability to accurately quantify both PEGylated and unconjugated Fab species. It was successfully validated with a LLOQ at 25.0 ng/ml.


Assuntos
Anticorpos Monoclonais/sangue , Fator D do Complemento/análise , Macaca fascicularis/sangue , Polietilenoglicóis/química , Animais , Anticorpos Monoclonais/administração & dosagem , Anticorpos Monoclonais/imunologia , Cromatografia de Afinidade , Cromatografia Líquida , Fator D do Complemento/administração & dosagem , Fator D do Complemento/imunologia , Injeções Intravítreas , Espectrometria de Massas em Tandem
19.
Anal Chem ; 91(23): 14896-14903, 2019 12 03.
Artigo em Inglês | MEDLINE | ID: mdl-31621311

RESUMO

This study describes the use of a multidimensional HPLC (2D and 4D) system for a faster and more effective characterization of an antibody-drug conjugate (ADC) product, compared to the standard off-line approach of fraction collection and off-line variant characterization. The size variants of an interchain cysteine-linked ADC were characterized to understand the effect of the different drug-to-antibody ratio (DAR) species on aggregate formation. For this purpose, the ADC product and a full panel of stressed samples were analyzed. The dimeric ADC species were baseline resolved from the main peak (Rs = 2.7) by UHP-SEC (ultra-high-performance size exclusion chromatography) under nondenaturing conditions using a buffered mobile phase containing 5% 2-propanol. A 2D-LC (SEC-HIC) method was then developed to compare the average DAR values of the main peak species vs the aggregates. A 4D-LC/MS method (SEC-reduction-digestion-RPHPLC) was also developed to determine levels of potential critical quality attributes (pCQAs) including aggregation, average DAR, oxidation, and deamidation, in a 2 h run. An average DAR value of 3.5-3.6 was found for the main peak using both 2D-LC and 4D-LC methods, and these values were consistent with DAR determined by the in-house reference hydrophobic interaction chromatography (HIC) method. The multidimensional LC approaches also showed an increase in the content of high-DAR species in the SEC fractions containing the aggregates. Overall the entire workflow of data acquisition is completed within a day using the multidimensional on-line approach, in comparison to multiple days required with the traditional off-line approaches.


Assuntos
Anticorpos/análise , Cromatografia Líquida de Alta Pressão/normas , Imunoconjugados/análise , Fragmentos de Peptídeos/análise , Anticorpos/química , Cisteína/química , Concentração de Íons de Hidrogênio , Interações Hidrofóbicas e Hidrofílicas , Imunoconjugados/química , Luz , Oxirredução , Mapeamento de Peptídeos , Proteólise , Soluções , Tripsina/química
20.
Sci Rep ; 7(1): 7896, 2017 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-28801661

RESUMO

Peptide mapping with liquid chromatography-tandem mass spectrometry (LC-MS/MS) is an important analytical method for characterization of post-translational and chemical modifications in therapeutic proteins. Despite its importance, there is currently no consensus on the statistical analysis of the resulting data. In this manuscript, we distinguish three statistical goals for therapeutic protein characterization: (1) estimation of site occupancy of modifications in one condition, (2) detection of differential site occupancy between conditions, and (3) estimation of combined site occupancy across multiple modification sites. We propose an approach, which addresses these goals in terms of summarizing the quantitative information from the mass spectra, statistical modeling, and model-based analysis of LC-MS/MS data. We illustrate the approach using an LC-MS/MS experiment from an antibody-drug conjugate and its monoclonal antibody intermediate. The performance was compared to a 'naïve' data analysis approach, by using computer simulation, evaluation of differential site occupancy in positive and negative controls, and comparisons of estimated site occupancy with orthogonal experimental measurements of N-linked glycoforms and total oxidation. The results demonstrated the importance of replicated studies of protein characterization, and of appropriate statistical modeling, for reproducible, accurate and efficient site occupancy estimation and differential analysis.


Assuntos
Produtos Biológicos/química , Bioestatística , Processamento de Proteína Pós-Traducional , Proteínas/química , Tecnologia Farmacêutica , Produtos Biológicos/farmacologia , Cromatografia Líquida de Alta Pressão , Mapeamento de Peptídeos , Proteínas/farmacologia , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...